Product introduction
Product Brief:
◆ Proprietary Infrared(NDIR) gas sensor
◆Can measure gas concentration of CO,HC,CO2,O2,NO simultaneously
◆With LCD and 6 keypads input.
◆Air/fuel ratio calculation and display automatically.
◆Chinese/English display screen,easy operation.
◆Oil temperature and RPM interface.
◆RS-232C interface and optional software.
◆Built-in Printer.
Specification:
◆Measurement range:
HC:0 - 9999ppm
CO:0 - 10%
CO2:0 - 20 %
O2:0 - 25%
NO:0 - 5000ppm
◆ Error:
HC :±12ppm or±5% (relative)
CO :±0.06% or±5% (relative)
CO2 : ±0.5% or±5% (relative)
O2 : ±0.1%or±5% (relative)
NO :±25ppm or±4% (relative)
◆Resolution:HC:1 ppm CO:0.01 % CO2:0.01 % O2:0.01 % NO:1 ppm
◆Response time:Less than10s(NDIR)
◆Warming up:10min
◆Power: AC220V ±10%,50HZ±1HZ
◆Weight:6.5kg
◆Dimension:266mm(width) × 360mm(depth)× 183mm(height)
Tuesday, January 12, 2010
Automobile Exhaust Gas Analyzer Gasboard-5020
Posted by sumas at 10:10 PM 0 comments
Engine RPM sensor Based on Vibration and Noise GASBOARD-8110
Product introduction
Introduction:
◆Use for dynamic and static engine RPM measurement.
◆Use for petrol and diesel engine.
◆Self-calibrating and automatic function monitoring.
◆Universal, connective to any exhaust gas analyzer
Specification:
◆Measure Target: 4 stroke petrol and diesel engines.
◆Signal input :Vibration and noise sensor .
◆Signal output :RS232 and TTL,LCD.
◆Power Supply:12V DC,350mA
◆Operation Temperature:5℃—45℃
◆Measurement range:
Speed Range Petrol Engines: 400 - 8000 rpm
Speed Range Diesel Engines: 400 - 6000 rpm
◆Weight:< 2KG
◆Dimensions:200 x 40 x 140 mm
Posted by sumas at 10:10 PM 0 comments
Labels: Engine RPM sensor Based on Vibration and Noise GASBOARD-8110
Portable Automobile Exhaust Gas Analyzer Gasboard- 5030
Product introduction
Product Brief:
◆ Proprietary Infrared(NDIR) gas sensor
◆Can measure gas concentration of CO,HC,CO2,O2,NO simultaneously
◆With LCD and 6 keypads input.
◆Air/fuel ratio calculation and display automatically.
◆Chinese/English display screen,easy operation.
◆Oil temperature and RPM interface.
◆RS-232C interface and optional software.
◆OBD2 function optional
Specification:
◆Measurement range:
HC:0 - 9999ppm
CO:0 - 10%
CO2:0 - 20 %
O2:0 - 25%
NO:0 - 5000ppm
◆ Error:
HC :±12ppm or±5% (relative)
CO :±0.06% or±5% (relative)
CO2 : ±0.5% or±5% (relative)
O2 : ±0.1%or±5% (relative)
NO :±25ppm or±4% (relative)
◆Resolution:HC:1 ppm CO:0.01 % CO2:0.01 % O2:0.01 % NO:1 ppm
◆Response time:Less than10s(NDIR)
◆Warming up:10min
◆Power: Rechargeable lithium cell inside
◆Weight: 2kg
◆Dimension: 225×172×61mm
Posted by sumas at 10:09 PM 0 comments
Labels: Portable Automobile Exhaust Gas Analyzer Gasboard- 5030